Power Line Transducers
DESCRIPTION

AE transducers convert various electrical power line parameters viz. Voltage, Current, Frequency, Power Factor, Active power, Reactive power, Apparent power into load independent DC current or voltage output. These are used in various electrical, thermal, chemical & other power plants to monitor processed data either locally or remotely, using various devices such as indicating meters, data loggers, recorders, SCADA systems.


FEATURES
Open & short circuit protected.
Current and Voltage output are indendent of load impedance.
Measurement of DC parameters.

ELECTRICAL SPECIFICATIONS
TYPE Ohm, DC / AC Voltage, DC / AC Current, Frequency, Summation, Power Factor, DC / AC Watt, Var, VA Transducers.
INPUT RANGE
  VOLTAGE 0 - 500V DC / 0 - 500V AC.
  CURRENT 0 - 5A DC (for higher ranges 50 - 300mV ext. Shunt) / 0 - 5A AC.
  FREQUENCY 50 / 60Hz ± 5hz., 400hz ± 20Hz. (other Frequency on request).
  POWER FACTOR 0.5% (lag) - unity - 0.5(lead). (Refer Note 4)
  RESISTANCE 0 - 500Ω for Ohm Transducer
ACCURACY 0.5% of f.s.d. for Ohm, Voltage, Current, Summation, Power Factor, Watt, Var, VA Transducers.
For Frequency Transducer - 0.2% of Centre frequency.
AUX. SUPPLY 63.5V, 110V, 220V, 230V, 240V, 380V, 415V, 440V AC ±10%, 50/60Hz.
24V, 48V, 110V, 220V DC ±10%
VA BURDEN For VOLTAGE ≤ 1.0, For CURRENT ≤ 0.5, for AUX Supply ≤ 4.0
OUTPUT RANGE
  CURRENT
MAX. LOAD
0 - 1mA 0- 5mA 0 - 10mA 0 - 20mA 4 - 20mA 10 - 0 - 10mA.
10kΩ 2kΩ 1kΩ 500Ω 500Ω 1kΩ
  VOLTAGE
MIN. LOAD
0 - 1V 0 - 5V 0 - 10V 1 - 5V 2 - 10V 10 - 0 10V
500Ω 2.5Ω 5kΩ 2.5kΩ 5kΩ 5kΩ
RIPPLE Maximum 0.5% of span.
OVERLOAD CAPACITY
  VOLTAGE continuous 120% of nominal  
  short term(10sec) 150% of nominal  
  CURRENT continuous 120% of nominal  
  short term(3 sec) 10 times of nominal  
RESPONSE TIME 300 msec.
OPEN CKT. VOLTAGE 22 Vmax.
IMPULSE VOLTAGE Peak Voltage of 5kV, Standardized impulsed waveform of 1.2 / 50µsec.
INSULN RESISTANCE Greater than 20 Mohms at 500V DC
DIELECTRIC TEST 2kV RMS for 1 minute (4kV on request)
OPERATING TEMP. 0°C to 55°C
STORAGE TEMP. -20°C to 70°C
HUMIDITY Upto 95% RH
CONFORMS TO I.S.12784 (Part 1)/ I.E.C. 688

MECHANICAL SPECIFICATION Transducers Panel Cum Din Rail Mounting
  Mounting Rail
EN 50022
2 mounting holes φ4.5mm for M4, 40 ~ 50 mm OR Equivalent screw M3 x 15 mm screw 4 terminals in 2 rows Lug width 6.0 ~ 6.4 mm 4 mounting holes Ø 5mm For M4,
20 ~ 25mm OR Equivalent screw
M3 X 10mm screw 8 Terminals in 2 Rows

MODEL PD1 PD2 PD3*
HEIGHT H = 123 mm H = 80mm H = 115 mm
AUX. SUPPLY AC / DC Auxiliary AC Auxiliary* DC Auxiliary
Type Ohm Transducer Summation Transducer
DC Voltage Transducer Single Phase Power Factor Transducer
DC Current Transducer 3 Phase Single Element Power Factor Transducer
Frequency Transducer Unipolar output Bipolar output*
AC Voltage Transducer 3 Phase 2 Element Watt / Var / VA Transducer*
AC Current Transducer 3 Phase 3 Element Watt / Var / VA Transducer*

* TYPE 3 Phase 2 Elemet & 3 Phase 3 Element Watt or Var Transducers with AC Auxiliary supply and Bipolar output are available in MODEL PD3.

Note :
1) Self - Powered AC Voltage, Current, Frequency , PF & Power Transducers are available on request.
  Self - Powered Voltage & Current transducers operate for input variation between 10% to 120% of the range.
  Self - Powered Frequency, Power and Power Factor Transducers operate on ±10% of rated voltage.
2) The individual output, in dual output transducers, are not isolated from each other.
3) Summation Transducers Maximum Inputs - 5 nos.; No isolation between any two inputs & between input & output.
4) Output of power factor transducers is proportional to phase angle.


Ordering information
1)Type 2) Model 3) Input Range 4 a) Output Range (Current / Voltage ) 4 b) Single or dual
5) Aux. Supply

ADDITIONAL INFORMATION
Power & Power Factor 1) Voltage (PTR) 2)Frequency 3) Current (CTR)
Summation 1) No. of inputs