| Digital Panel Voltmeter / Ammeter / Frequency Meters | ||
![]() |
||
| DESCRIPTION | ||
|
Digital
Panel Meters operate on the principle of dual slope integration. It is
available in two types i.e. |
||
| FEATURES | |
| • | Low cost. |
| • | Seven segment red & green colour LED display with 0.5" & 1 " size. |
| • | AC current input is incorporated with builtin CT of 1Amp or 5Amp for isolation. |
| • | High accuracy. |
| • | AC / DC signal measurement |
| ELECTRICAL SPECIFICATIONS | |||
| Parameters | Type | ||
| Digital panel meter | Digital frequency meter | ||
| 3 ½ digit | 4 ½ digit | 4 digit | |
| Mounting | Panel | Panel | Panel |
| Measuring Range - Voltage | 0 - 650V AC | 0 - 650V AC | 600V AC |
| 0 - 700 V DC | 0 - 700 V DC | - | |
| Measuring
Range - Current AC (with internal CT) DC (with internal Shunt) |
1A / 5A 5A |
1A / 5A 5A |
- - |
| Frequency | 40 - 400Hz. | 40 - 400Hz. | 30 - 10 k Hz. |
| Resolution | 0.001 to 1 count depending upon measuring range |
0.0001 to 1 count depending upon measuring range |
Depending upon measuring range |
| ACcuracy | 0.5% of f.s.d. ±2 Digits | 0.2% of reading ±2 Digits | |
| Auxiliary Supply | 63.5V / 110V / 240AC ± 10% | 63.5V / 110V / 240V
AC ± 10% |
|
| VA Burden for Aux. supply | Less than 4VA | Less than 4VA | |
| Input impedance for voltage | 1 Mohms | 1 Mohms | |
| VA Burden
Current Voltage |
0.5VA 1VA |
- 1VA |
|
| Insulation resistance | Greater than 20 Mohms at 500V DC | Greater than 20 Mohms
at 500V DC |
|
| Dielectric test | 2kV RMS for 1 minute. | 2kV RMS for 1 minute. | |
| Operating temperature | 0°C to 55°C | 0°C to 55°C | |
| Storage temperature | -20°C to 70°C | -20°C to 70°C | |
| Humidity | Upto 95% RH | Upto 95% RH | |
| Sampling rate | 3 samples / Sec. | 3 samples / Sec. | |
| Over range indication | MSD indication "1" & all other digits blank. Polarity sign is preserved. |
All digits blinking
with "0" indication & polarity sign is preserved. |
- |
| Protection | IP20 | IP20 | |
| Maximum indication | 1999 | 19999 | - |
| MECHANICAL CONSTRUCTION | |
![]() |
![]() |
![]() |
![]() |
| MODEL | A1 | A2 | A3 | A4 |
| SIZE (mm) | 48 x 96 x 115 | 72 x 144 x 130 | 72 x 72 x 110 | 96 x 96 x 70 |
| PANEL CUT OUT(mm) | 45+0.6 x 92 +0.7 | 68+0.7 x 138+1.0 | 68 x 68+0.7 | 92 x 92+0.8 |
| WEIGHT (approx. gms) | 520 | 1100 | 375 | 500 |
| Note : | |
| • | Active, reactive & apparent power indicators are to be used with external transducer. |
| • | For AC current measurement above 5Amp, external CT is to be used. |
| • | For DC current measurement above 5Amp, external shunts is to be used. |
| Ordering information | ||
| 1) Type
2) Model 3) Measuring
Range 4) Display
height & color
5) Auxilliary supply 4)
Resolution 5) Auxiliary supply 6) Resolution. |