Digital Panel Voltmeter / Ammeter / Frequency Meters
DESCRIPTION

Digital Panel Meters operate on the principle of dual slope integration. It is available in two types i.e.
3½ digit & 4½ digit. Digital frequency meter incorporates microcontroller with crystal oscillator to display the frequency. It is available in 4 digit type.


FEATURES
Low cost.
Seven segment red & green colour LED display with 0.5" & 1 " size.
AC current input is incorporated with builtin CT of 1Amp or 5Amp for isolation.
High accuracy.
AC / DC signal measurement

ELECTRICAL SPECIFICATIONS
Parameters Type
Digital panel meter Digital frequency meter
3 ½ digit 4 ½ digit 4 digit
Mounting Panel Panel Panel
Measuring Range - Voltage 0 - 650V AC 0 - 650V AC 600V AC
0 - 700 V DC 0 - 700 V DC -
Measuring Range - Current
AC (with internal CT)
DC (with internal Shunt)
1A / 5A
5A
1A / 5A
5A
-
-
Frequency 40 - 400Hz. 40 - 400Hz. 30 - 10 k Hz.
Resolution 0.001 to 1 count
depending upon
measuring range
0.0001 to 1 count
depending upon
measuring range
Depending upon measuring
range
ACcuracy 0.5% of f.s.d. ±2 Digits 0.2% of reading ±2 Digits
Auxiliary Supply 63.5V / 110V / 240AC ± 10% 63.5V / 110V / 240V AC
± 10%
VA Burden for Aux. supply Less than 4VA Less than 4VA
Input impedance for voltage 1 Mohms 1 Mohms
VA Burden
Current
Voltage
0.5VA
1VA
-
1VA
Insulation resistance Greater than 20 Mohms at 500V DC Greater than 20 Mohms at
500V DC
Dielectric test 2kV RMS for 1 minute. 2kV RMS for 1 minute.
Operating temperature 0°C to 55°C 0°C to 55°C
Storage temperature -20°C to 70°C -20°C to 70°C
Humidity Upto 95% RH Upto 95% RH
Sampling rate 3 samples / Sec. 3 samples / Sec.
Over range indication MSD indication "1"
& all other digits
blank. Polarity
sign is preserved.
All digits blinking
with "0" indication
& polarity sign is
preserved.
-
Protection IP20 IP20
Maximum indication 1999 19999 -

MECHANICAL CONSTRUCTION

MODEL A1 A2 A3 A4
SIZE (mm) 48 x 96 x 115 72 x 144 x 130 72 x 72 x 110 96 x 96 x 70
PANEL CUT OUT(mm) 45+0.6 x 92 +0.7 68+0.7 x 138+1.0 68 x 68+0.7 92 x 92+0.8
WEIGHT (approx. gms) 520 1100 375 500

Note :
Active, reactive & apparent power indicators are to be used with external transducer.
For AC current measurement above 5Amp, external CT is to be used.
For DC current measurement above 5Amp, external shunts is to be used.

Ordering information
1) Type 2) Model 3) Measuring Range 4) Display height & color 5) Auxilliary supply 4) Resolution
5) Auxiliary supply 6) Resolution.
Home